Product Specifications
Brand
ResMed
What's in the package?
1x Device 1x HumidAir™ humidifier (optional) 1x Air tubing
1x Power supply unit
1x Travel bag
1x SD card (already inserted)
1x Power supply unit
1x Travel bag
1x SD card (already inserted)
Compatibility
The Lumis 150 VPAP ST-A is designed for compatibility with the general range of ResMed masks, including Full Face Masks, Nasal Masks, and Nasal Pillow Masks. Specific compatible masks include the AirFit™ F20 (Full Face), AirTouch™ F20 (Full Face), AirFit™ N20 (Nasal), and AirFit™ P10 (Nasal Pillow).
Physical Specification
Dimensions (H x W x D) (Device only): 116 mm x 205 mm x 150 mm * Dimensions (H x W x D) (Device with HumidAir humidifier): 116 mm x 255 mm x 150 mm * Weight (Device with HumidAir heated humidifier): Approximately 1336 g
Connectivity
The ResMed Lumis 150 VPAP ST-A features built-in cellular wireless connectivity (available in 4G, 3G, or 2G models) for remote patient management via the AirView cloud system. For local data storage, an SD card is included and utilized to record both summary and detailed therapy data. Direct Wi-Fi or Bluetooth connections for patient data transfer are not specified as core features.
Power Performance
Power Supply Unit: 90W * Power Consumption (Input Range): 100–240V, 50–60Hz, 1.0–1.5A * Power Consumption (Typical/Peak): 53W (57VA) typical power consumption; 104W (108VA) peak power consumption
Sound Level
26.6 dBA (or 27 dBA) with an uncertainty of 2 dBA (measured in CPAP mode)
Therapy Mode
Bi-PAP -CPAP
Operating Pressure Range
2–25 cm H₂O (2–25 hPa) in S, T, ST, PAC, and iVAPS modes; 4–20 cm H₂O (4–20 hPa) in CPAP mode
Flow Sensor Range
-70 to +180 l/min
Ramp Time Setting
Off or between 5 to 45 minutes
Humidity Level Setting
Off or between 1 and 8
Comfort Feature
Ramp Down
This feature gradually and comfortably reduces the therapeutic pressure over a fixed 15-minute period when the patient initiates stopping therapy. After the Ramp Down is complete, the device continues to run at a low pressure until explicitly turned off, easing the patient's transition to spontaneous breathing. The device also has a standard Ramp feature to ease into the prescribed pressure at the start of the session.
This feature gradually and comfortably reduces the therapeutic pressure over a fixed 15-minute period when the patient initiates stopping therapy. After the Ramp Down is complete, the device continues to run at a low pressure until explicitly turned off, easing the patient's transition to spontaneous breathing. The device also has a standard Ramp feature to ease into the prescribed pressure at the start of the session.
Warramty